Up to date Measurement, Control and Adjustment of ohmic load as well as Infrared emitters are the prerequisites to use Infrared systems for heating processes in an efficient and cost effective way.
| Technical Data | IC 161 | IC 163 | IC 321 | IC 323 | IC 551 | IC553 | |
| Max. output 230V load | KW | 3,5 | 10,5 | 7 | 21 | 12,6 | 38 |
| Max. phase voltage with 230V load | A | 15 | 3×15 | 30 | 3×30 | 55 | 3×55 |
| Max. output 400V load | KW | 6 | 18 | 12 | 36 | 22 | 66 |
| Max. phase voltage with 400V load | A | 15 | 3×8,5 | 30 | 3×17,5 | 55 | 3×55 |
| Nominal voltage | V | 230/400 | 230/400 | 230/400 | 230/400 | 230/400 | 230/400 |
| Kind of current | Hz | 50/60 | 50/60 | 50/60 | 50/60 | 50/60 | 50/60 |
| Mains supply Maximum safety |
CEE 5×16 |
CEE 5×16 |
CEE 5×32 |
CEE 5×32 |
Clamps | Clamps | |
| Preliminary fuse | A | 16 | 16 | 32 | 32 | 63 | 100 |
| Current type N/PE or PEN loaded phases | 1/2 | 3 | 1/2 | 3 | 1/2 | 3 | |
| Number of automatic interrupters | – | – | 6 | 6 | 8 | 24 | |
| Number of power controllers | 1 | 3 | 1 | 3 | 1 | 3 | |
| Number of possible process controllers | 1 | 3 | 1 | 3 | 1 | 3 | |
| Connection points for fans 230V/50Hz incl. residual motion and monitoring |
2 | 2 | 2 | 2 | 2 | 4 | |
| Supply external equipment 230V AC / 24VDC |
yes | yes | yes | yes | yes | yes | |
| Max. surrounding temperature | °C | 30 | 30 | 30 | 30 | 30 | 30 |
| Dimensions | mm | 600×600 | 600×600 | 760×600 | 760×600 | 760×760 | 1000×800 |
| Protection type Optional protection type |
IP 42 IP 54 |
IP 42 IP 54 |
IP 42 IP 54 |
IP 42 IP 54 |
IP 42 IP 54 |
IP 42 IP 54 |
|
NOTE:The max. load can only be achieved if all IR emitters are connected at a phase-symmetrical rate.
FEATURES OF CONTROL IC:
- The housing contains control ready for connection.
- Continuously adjustable linear power output.
- Potentiometers or external analog and digital control signals specify the control points.
- Monitoring circuit to recognize failures.
- Automatic interrupter to ensure an optimum conductor cross section to the load.
- Main switch to disconnect the control from mains.
- Can be easily integrated into superset systems.
Options:
- Set-point specification by a microprocessor controller with Ramp function.
- Connection to a data measuring device.
- Partial-load error monitoring of all load circuits.
- Special equipment on request.