Up to date Measurement, Control and Adjustment of ohmic load as well as Infrared emitters are the prerequisites to use Infrared systems for heating processes in an efficient and cost effective way.

Technical Data IC 161 IC 163 IC 321 IC 323 IC 551 IC553
 
Max. output 230V load KW 3,5 10,5 7 21 12,6 38
Max. phase voltage with 230V load A 15 3×15 30 3×30 55 3×55
Max. output 400V load KW 6 18 12 36 22 66
Max. phase voltage with 400V load A 15 3×8,5 30 3×17,5 55 3×55
Nominal voltage V 230/400 230/400 230/400 230/400 230/400 230/400
Kind of current Hz 50/60 50/60 50/60 50/60 50/60 50/60
Mains supply
Maximum safety
  CEE
5×16
CEE
5×16
CEE
5×32
CEE
5×32
Clamps Clamps
Preliminary fuse A 16 16 32 32 63 100
Current type N/PE or PEN loaded phases   1/2 3 1/2 3 1/2 3
Number of automatic interrupters   6 6 8 24
Number of power controllers   1 3 1 3 1 3
Number of possible process controllers   1 3 1 3 1 3
 
Connection points for fans 230V/50Hz
incl. residual motion and monitoring
  2 2 2 2 2 4
Supply external equipment
230V AC / 24VDC
  yes yes yes yes yes yes
 
Max. surrounding temperature °C 30 30 30 30 30 30
Dimensions mm 600×600 600×600 760×600 760×600 760×760 1000×800
Protection type
Optional protection type
  IP 42
IP 54
IP 42
IP 54
IP 42
IP 54
IP 42
IP 54
IP 42
IP 54
IP 42
IP 54

 

NOTE:The max. load can only be achieved if all IR emitters are connected at a phase-symmetrical rate.

FEATURES OF CONTROL IC:

  • The housing contains control ready for connection.
  • Continuously adjustable linear power output.
  • Potentiometers or external analog and digital control signals specify the control points.
  • Monitoring circuit to recognize failures.
  • Automatic interrupter to ensure an optimum conductor cross section to the load.
  • Main switch to disconnect the control from mains.
  • Can be easily integrated into superset systems.

Options:

  • Set-point specification by a microprocessor controller with Ramp function.
  • Connection to a data measuring device.
  • Partial-load error monitoring of all load circuits.
  • Special equipment on request.
GET IN TOUCH

Please contact us if you have any question.
We will do our best to help you.